Guangdong Jiema Energy Saving Technology Co.,Ltd

Products

Home > Products > Shell And Tube Heat Exchanger > Floating Head Heat Exchanger > Tube Sheet Heat Exchanger for Slop Oil Cooling

  • Tube Sheet Heat Exchanger for Slop Oil Cooling
  • Tube Sheet Heat Exchanger for Slop Oil Cooling
  • Tube Sheet Heat Exchanger for Slop Oil Cooling
  • Tube Sheet Heat Exchanger for Slop Oil Cooling
  • Tube Sheet Heat Exchanger for Slop Oil Cooling

Tube Sheet Heat Exchanger for Slop Oil Cooling

  • $300
    ≥1
    Piece/Pieces
Payment Type:
T/T,L/C
Incoterm:
FOB,Express Delivery,CFR,CIF,EXW,DDU
Min. Order:
1 Piece/Pieces
Transportation:
Land,Ocean,Air,Express
Port:
Guangzhou
Share:
  • Product Description
Overview
Product Attributes

BrandJiema

MaterialCarbon steel, Stainless steel

UsageCooling, Heating

Supply Ability & Additional Information

PackagingPlywood box

Productivity 1000 pcs per month

TransportationLand,Ocean,Air,Express

Place of OriginGuangzhou

Supply Ability1000 pcs per month

CertificateISO 9001:2015 CE

HS Code8419500090

PortGuangzhou

Payment TypeT/T,L/C

IncotermFOB,Express Delivery,CFR,CIF,EXW,DDU

Packaging & Delivery
Selling Units:
Piece/Pieces
Package Type:
Plywood box

Tube Sheet Heat Exchanger for Slop Oil Cooling


Tube Sheet Heat Exchanger for Slop Oil Cooling or Shell and Tube Chiller, from its on-site photographs, has a distinct mechanics from other Shell and Tube Heat Exchangers such as Fixed Tube Heat Exchanger and U Tube Heat Exchanger. To illustrate, its rear head cover is fixed and cannot be removed. At the same time, the floating head cover at the front, is free to move inside the shell, namely, to move up and down.

         Tube Sheet Heat Exchanger for Slop Oil Cooling     Tube Sheet Heat Exchanger

With that being said, thermal expansion of the S&T Heat Exchanger is of no harm to the equipment. Beyond that, tube bundles of our Tube Sheet Heat Exchanger allows thorough cleansing after being removed from the shell. However, there is no such thing as a free lunch. The multifunctional characteristics of Shell and Tube Chiller comes with complicated fabrication and high price. It is mostly applied in fields where high temperature difference and heavy fouling are the main concerns.

 

⛵ Key Points to the Installation of S&T Heat Exchanger

 

1. Hydrostatic test pressure would be 1.5 times higher than the operating pressure with the duration of 10 minutes; (Steam:+0.3MPa;Hot water:+0.4MPa)


2. Space shall be left for future removal of the tube bundles; estimated distance between the floating head and the wall/roof of the room should be no less than the total length of the equipment;


3. Relevant valves and digital instruments shall be installed at a height that is best suitable for operation and observation;


4. Vertical clearance between the highest location of upper attachment(mostly safety valve) and the floor shall meet the installation requirements and not less than 0.2m.

        Shell and Tube Chiller     S&T Heat Exchanger

⛵ Application of Tube Sheet Heat Exchanger

 

Tube Sheet Heat Exchanger, also Shell and Tube Chiller, is big hit among manufacturers from the chemical engineering industry, petroleum industry, energy industry and others. It helps our customers to realize heat exchanging under high temperature and pressure requirements with easy assembly and cleansing.

 

⛵ About Our Company

 

Guangdong Jiema Energy Saving Technology Co LtdWith rich practical experience in various industrial and civil applications, our technical professionals can provide our customers with accurate and reliable solutions, and then select a corresponding heat exchanger equipment according to the real requirements of customers.

 


⛵ FAQ of S&T Heat Exchanger

S&T Heat Exchanger Production

 


1. Is Tube Sheet Heat Exchanger removable?

Yes, it is. Our Tube Sheet Heat Exchanger can be removed from the floating head and be cleaned.

 

2. What is baffle in Shell and Tube Chiller?

Baffle is a flat plate installed inside the shell at a vertical angle with an attempt to increase the velocity of the shell side fluid and its number of passes. As a result, the heat transfer area multiplies by a great amount and so as the heat exchange efficiency.




Product Categories : Shell And Tube Heat Exchanger > Floating Head Heat Exchanger

Email to this supplier
  • *Subject:
  • *To:
    Ms. Abby
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters

Home > Products > Shell And Tube Heat Exchanger > Floating Head Heat Exchanger > Tube Sheet Heat Exchanger for Slop Oil Cooling

Send Inquiry
*
*

Send Inquiry

Tel:+86-020-82453507

Fax:

Mobile Phone:+8613662249479Contact me with Whatsapp

Email:jmheatexchanger@163.com

Address:No.73, Bigang Road, Nangang Street, Huangpu District, , Guangzhou, Guangdong

Mobile Site

Home

Product

Whatsapp

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send